CONGRATULATIONS

You are now the owner of a Goulds Water Technology

pump. This pump was carefully inspected and subjected

to final tests before releasing for shipment. In order to

assure maximum performance, please follow the simple

instructions in this manual.

RECOMMENDED PRECAUTIONS

1. Avoid system pressures that may exceed the maxi-

mum working pressure of the pump.

2. Should the fluid temperature rise more than 50ºF.

above ambient, expansion joints must be installed on

both the suction and discharge ports to relieve any

stress on the pump casing.

3. All electrical wiring of the pump installation must be

done by a licensed electrician who will observe all

national and local electrical codes. All motors require

a magnetic starter with current overload protection.

4. No modifications, additions or deletions should be

made to the pump, without prior approval of the

factory.

5. In systems where shock wave pressures may be gener-

ated, protective devices such as check valves/gate

valves, etc., must be installed on the discharge line

to prevent shock pressures from entering the pump

casing.

6. In systems containing discharge check valves, gate

valves, etc., the pump will not prime against a closed

valve. Check the discharge valves making sure they

are open before attempting to prime the pump. If

there is a possibility of air being entrapped in the

pump casing, install an automatic venting device to

bleed off the air.

7. This pump is designed primarily for water use. Before

pumping other liquids, read carefully the CAUTION

below.

8. Overheated pumps are dangerous. Burns or explosion

could occur due to steam pressure. Operating pumps

with suction and discharge closed is one cause of se-

vere overheating. If overheating of the pump occurs:

1. Stop pump immediately, 2. Allow pump to cool, 3.

Slowly and cautiously vent pump.

9. Drain casing completely when servicing pumps han-

dling volatile or harmful liquids.

10. Do not use in a combustible atmosphere.
11. Make daily checks of the tightness of suction and

discharge pipe, drain, filter plug and pump gaskets.

Operation should not proceed until all of the above

items have been checked and are tight.

12. After servicing the pump, always install the coupling

guards, belt guards and other safety devices as origi-

nally found prior to disassembly.

The performance of Goulds Water

Technology are based upon clear, cold,

fresh water with suction conditions as shown on the

performance curve. If used to pump other liquids, pump

performance may differ from rated performance based

on the different specific gravity, temperature, viscosity,

etc. of the liquid being pumped. A standard pump may

not be safe for pumping all types of liquids, such as toxic,

volatile or chemical liquids, or liquids under extreme

temperatures or pressures. Please consult your Goulds

Water Tehcnology catalog as well as local codes and

general references to determine the appropriate pumps

for your particular application. Since it is impossible

for us to anticipate every application of a Goulds Water

Tehcnology pump, if you plan to use the pump for a

non-water application, consult Goulds Water Tehcnology

beforehand to determine whether such application may

be proper or safe under the circumstances. Failure to do

so could result in property damage or personal injury.

OPERATING INSTRUCTIONS

GENERAL
• Our shipping container has been specifically designed

to prevent transit damage. However, any indications

of damage or shortage should be carefully noted on

the delivery ticket and a claim filed promptly with the

carrier.

PROPER LOCATION
• By placing your pump on a firm, level foundation or

between firmly supported pipelines, you reduce harm-

ful vibrations and unnecessary noises.

• While EV series pumps are self-priming and may be

located above the source of liquid supply, best pump

operation is obtained by locating the pump as close as

possible to the liquid being handled, keeping in mind a

pump can push liquid more effectively than it can pull

or draw liquid. Provide the necessary space around the

pump for future inspection and servicing of the unit.

PIPING
• All piping should be independently supported to elimi-

nate excessive strain on the pump. Avoid unnecessary

friction losses. Keep your piping as short as possible

and use the fewest possible elbows and fittings. Pipe

joint compound that will not dissolve in the liquid

being pumped should be used on all joints. Gate valves

combined with unions or flanges, on both sides of the

pump, will facilitate pump removal without disturbing

the piping. It is occasionally advantageous to use suc-

tion pipe one size larger than that for which the pipe

is fitted. Eccentric reducers should be used to change

pipe sizes.

STRAINER ADVISABLE
• Protect your investment. Install a strainer on the suc-

tion line. This will eliminate clogging of the pump,

poor performance and excessive wear. A 16 mesh

strainer submerged one foot below the liquid level is

adequate for EV series pumps. In-line strainers are

available from your Goulds Water Technology dealer.

Piping that has a continuous rise will facilitate draining

the system.

VALVES
• Install a check valve on the discharge side of the pump.

This will prevent high surge back pressures from

damaging the pump. If the pump is disconnected this

check valve will prevent the liquid from draining the

discharge line.

• Some installations may require the throttling of the

pump. Gate valves may be used on the discharge side.

Place the check valve between pump and gate valve.

CAUTION

Advertising