Aquavar ABII Controller

Typical Installation

This diagram shows a set-up for municipal water connection. This allows pump
maintenance without main line shut-off.

Home Supply

Water Main

Check Valve

Isolation Valves

Unions

Check Valve

To Drain

Relief

Valve

Gauge

Tank

AquaBoost

Controller

Circuit

Breaker

Disconnect

Transducer

Motor/Pump

AquaBoost II Required Components:

1. Pump with Motor

2. AquaBoost II Controller with Integral Pressure Sensor Cable

3. Pressure Tank

4. Pressure Sensor

5. Mounting Kit

6. Tank Tee with Pipe Plug

7. Pressure Gauge