Aquavar abii wiring diagram, 1 and 2 hp 3 and 5 hp – Xylem IMS ABII 1 Aquavar ABII Quick Start Guide User Manual

Page 4

Advertising
background image

Input
230V

1 Phase

GND

L1

L2 (N)

See Manual For

Switch Settings

Applic.

Type

Output

To Motor

1 2 3 4

1 2 3 4

Pressure

Transducer

Input (Wht)

+5V

(R

ed)

C

om.
(Blk)

T1 T2

T3 GND

Motor

Overload

Setting

Line output to motor.

Correct motor rotation

determines order of colors.

Pressure

Transducer

Line input power from

2-pole disconnect or

circuit breaker.

GREEN

BLA

CK

BLA

CK

GREEN

WHITE

RED

BLA

CK

BL

UE

RED

BLA

CK

Note: Verify controller voltage input on label. 115 volt or 230 volt.

Note: Use 2 pole disconnect
or circuit breaker.

Aquavar ABII Wiring Diagram

1 AND 2 HP

3 AND 5 HP

INPUT BLOCK

* Input Power Supply

Single Phase

208-240 VAC

OUTPUT BLOCK

L1

L2

GND

GND RED

BLK YEL

GROUND

GROUND

THREE PHASE

MOTOR

OUTPUT

230 VOLT

THREE PHASE

MOTOR

Xylem Inc.

www.xyleminc.com

© 2011 Xylem Inc. IMS-ABII-2 December 2011