COUPLING INSTALLATION:

(SEE FIGURES 9 and 10)

1. Check all mating faces with a fine flat file before

installation. Remove all burrs from face.

2. Apply a thin film of oil on the pump key (730) and

insert key into headshaft keyway seat.

3. Gently lower pump hub of coupling (614) onto

headshaft.

4. Thread on the adjusting plate (613) onto the

headshaft until flush with top of the headshaft.

5. Clean driver shaft by removing all grease and burrs.

Try to fit the key on the driver hub (610) before

installing it to the driver shaft.

6. Apply a thin film of oil to the driver key (730) and

insert key into drive shaft keyway seat. Place the

driver hub (610) onto the drive shaft and with key

slide it up the drive shaft until the annular groove

is exposed. Install split ring (722) in the groove and

slide driver hub down over the split ring to capture

it.

Figure 9

7. If the pump is supplied with an adjustable spacer

coupling (see figure 10), install spacer (612) be-

tween head shaft and driveshaft hubs. Secure with

capscrews (759) and hex nuts (735).

IMPELLER ADJUSTMENT

Improper impeller adjustment could cause

contact between the rotating and stationary

parts, resulting in a spark and heat generation.

Impeller adjustment is identical for all motors and

right angle gear drives. Adjustment is accomplished by

turning the adjusting plate (613). (See figure 11 or 12).

The correct adjustment is listed on the Outline Drawing

for the specific unit. If the pump has thrust pot, do not

adjust the impeller position until the thrust has been

installed and adjust the impeller position by using the

adjust nut on the thrust pot.

Figure 10

NOTE: Mechanical seal, when provided, must not be

secured to the shaft prior to impeller adjustment.

(open or enclosed type impellers). Shaft must

move up or down within the seal Assembly.
For pumps handling liquids between –50º to

200º F, impeller adjustment can be made under

ambient conditions. For liquids in excess of

this range, it is recommended that impeller

adjustment be made after the pump surface

temperature has reached an equilibrium when

charged with the pumpage. In those cases, where

this is not feasible due to safety consideration

or impossible due to external ice build up in

cryogenic applications, refer to factory for

specific instructions.

OPEN IMPELLERS

1. With the impellers touching the bottom of the

bowls, turn the adjusting plate (613) towards the

driver hub (610) or spacer (612) obtain 0.015 inch

clearance between the adjusting plate and driver

hub or spacer for the first 10 feet of column. Add

0.010” for each additional 10 feet of column. See

figure 10 or 11. Note: The determination of driver

shaft end play can be critical and should be added

to this setting. For larger pumps over 8”, this

amount may be too little; please refer to Outline

Drawing.