Xylem IMVIC R01 Model VIC Vertical Industrial Turbine Can Pumps User Manual

Page 25

Advertising
background image

25

TROUBLESHOOTING

TROUBLE

PROBABLE CAUSE

REMEDY

1. Pump does not start

A. Electrical circuit open or not

Check circuit and correct.

completed

B. Improper lateral adjustment.

Reset impeller adjustment,

Impeller on bottom.

See pages 17 or 18.

C. Low voltage supplied to

Check whether driver wiring is

electric driver

correct and receiving full voltage.

D. Defective motor

Consult factory.

2. No liquid delivered

A. Discharge valve closed

Be sure the discharge valve is in

full open position.

B. Speed is too low

Check if driver is directly across

the line and receiving full voltage.

C. Damaged bowl assembly;

Pull pump and repair all

Broken or disconnected shaft

damaged components.

D. Driver with reduced voltage, or

Check RPM, voltage, and amps.

Reduced current starting does

not come up to speed

E. Barrel/Discharge head not

Open vent.

properly vented.

F. Suction valve closed.

Confirm valve position.

3. Not enough liquid

A. Same as items 2-A thru 2-E

Same as items 2-A thru 2-E.

B. Cavitation

Insufficient NPSH available.

Consider lowering the bowl

assembly by adding column.

C. Impellers adjusted too high

See pages 17 or 18.

D. Air or gas in the water

If successive starts and stops

do not remedy, lower pump if

possible, or close discharge

valve to maintain well pumping

level at a lower GPM.

E. Excessive pump wear

Pull pump and repair as required.

F. Suction valve partially open

Confirm valve position.

4. Not enough pressure

See (3.) Not enough liquid.

See (3.) Not enough liquid.

5. Pump works for a while

A. Excessive horsepower required.

Use larger driver. Consult factory.

and quits

B. Pumping higher viscosity or

Test liquid for viscosity and

specific gravity liquid than

specific gravity.

designed for.

C. Mechanical failure of

Check bearings and impellers for

critical parts

damage. Any irregularities in

these parts will cause a drag

on the shaft.

D. Suction strainer clogged

Pull pump and clean the strainer.

E. Misalignment

Realign pump and driver.

F. Same as 2E, 2F and 3F

Same as 2E, 2F and 3F

Advertising