SectIOn 4

INSTAllATION INSTRUCTIONS

A. SYSTEM PIPING AND UNIT INSTALLATION

_____ 1. Is the unit base properly leveled and

secured?

_____ . Are all lubrication points properly

lubricated?

_____ . Is the shut-off valve to the pump suction

open?

_____ . Is the shut-off valve on the discharge

line open?

_____ 5. Is the bypass valve, if used, closed?

_____ 6. Is the piping properly supported to

prevent strains on unit?

_____ 7. Is the system, including the pumps,

purged of debris and air?

SEAL DAMAGE MAY OCCUR. DO

NOT RUN PUMPS DRY. FILL AND

VENT THE PUMP VOLUTE PRIOR TO OPERATION.

FAILURe tO FOLLOW tHeSe InStRUctIOnS

cOULD ReSULt In PROPeRtY DAMAGe AnD/OR

MODeRAte PeRSOnAL InJURY.

B. ELECTRICAL WIRING AND CONTROL SETTINGS

_____ 1. Does the feeder line voltage correspond

to the unit voltage? Check the unit

nameplate or motor terminal

connection.

ELECTRICAL SHOCK HAZARD.

INSPECT ALL ELECTRICAL CONNEC-

TIONS PRIOR TO POWERING THE UNIT. WIRING

CONNECTIONS MUST BE MADE BY A QUALIFIED

ELECTRICIAN IN ACCORDANCE WITH ALL APPLI-

CABLE CODES, ORDINANCES, AND GOOD PRAC-

TICES. FAILURe tO FOLLOW tHeSe InStRUc-

tIOnS cOULD ReSULt In SeRIOUS PeRSOnAL

InJURY, DeAtH AnD/OR PROPeRtY DAMAGe.

_____ . Are the feeder wires correctly sized for

the load?

CONDUIT GROUNDS ARE NOT AD-

EQUATE. A SEPARATE GROUND WIRE

MUST BE ATTACHED TO THE GROUND LUG PRO-

VIDED IN THE ENCLOSURE TO AVOID POTENTIAL

SAFETY HAZARDS. FAILURe tO FOLLOW tHeSe

InStRUctIOnS cOULD ReSULt In SeRIOUS

PeRSOnAL InJURY, DeAtH AnD/OR PROPeRtY

DAMAGe.

_____ . Have all the power terminals in the

control panel been checked for

tightness? This is imperative since

stranded wires tend to "flow" and

become loose after initial installation.

ELECTRICAL SHOCK HAZARD.

SINGLE PHASE OR THREE PHASE AC

POWER. DISCONNECT AND LOCKOUT POWER

BEFORE SERVICING THE UNIT. FAILURe tO FOL-

LOW tHeSe InStRUctIOnS cOULD ReSULt In

SeRIOUS PeRSOnAL InJURY, DeAtH AnD/OR

PROPeRtY DAMAGe.

_____ . Are the pressure controls correctly set?

The pressure switch(es) need to be set

for proper operation. Any subsequent

change in system operating conditions

may require resetting the controls. For

best results, use compressed air and a

continuity meter (across the switch) to

reset the controls. The legend plate on

the control indicates approximate

readings only, therefore, should be used

with caution.

SectIOn 5

TROUblESHOOTING

TROUBLESHOOTING LIVE CON-

TROL PANELS EXPOSES PERSON-

NEL TO HAZARDOUS VOLTAGES. ELECTRICAL

TROUBLESHOOTING MUST ONLY BE DONE BY A

QUALIFIED ELECTRICIAN. FAILURe tO FOLLOW

tHeSe InStRUctIOnS WILL ReSULt In SeRIOUS

PeRSOnAL InJURY, DeAtH AnD/OR PROPeRtY

DAMAGe.

PUMP WILL nOt OPeRAte:

1) Check incoming power
) Check power fuses. Replace if blown.
) Check transformer fuses. Replace if blown.
) Check to see that control voltage is 10 volt.
5) Check motor overload. Reset if tripped.
6) Momentarily turn HOA switch to HAND position

and back to OFF. Does starter pull in? If starter

doesn’t pull into go to next step. If it does pull in

go to step 10.

7) Turn HOA switch to HAND position. Check volt-

age across terminals for coil in starter. If voltage

is present and the starter is not pulled in, the coil

is defective and must be replaced. If voltage isn’t

present go to step 8.

8) With HOA still in HAND, check voltage between

HOT side of starter coil and the neutral (white)

wire. 10 volts should be measured. If voltage is

measured go to step 9.

9) With HOA still in HAND, check voltage between

the hot side of coil & neutral (white wire) for

over load block. 10 volts should be measured. If

voltage is measured replace the overload block.

If no voltage is present contact your local Goulds

Pumps representative to service control circuit.