Vortex Installation, Operation and Maintenance Manual

9

Installation Parts

Check if all components for your installation are delivered.

Figure 3

Direction of Rotation

A correct direction of rotation is essential for proper operation. This can be checked as
follows:

• Put the pump in horizontal position and start the pump. Look at

impeller through the suction opening, the correct direction of rotation
is counterclockwise (see arrow on pump casing, Figure 3). or:

• Starting the pump will give a recoil on the pump frame. Looking at the

motor (in vertical position see Figure 4), the recoil is counterclockwise.

Take care! The recoil can be very powerful!
Don't go too near rotating parts!

Figure 4

Current Check

Note the maximum current from the data plate.
Apply an ammeter to one of the phase wires during normal operation. Check that the
current is not higher than the value on the data plate. If so check for:

• voltage (too low?) ± 5% nameplate
• specific gravity or viscosity of the fluid

(too high?)

• blocked impeller?
• direction of rotation correct?

If the problem cannot be solved contact your dealer.

Start Up Procedures (continued)

WARNING

Hazardous voltage

can shock, burn or

cause death.