V. transportation and storage, Warning, Caution – Xylem IM205 Vortex Series User Manual

Page 18

Advertising
background image

16

Vortex Installation, Operation and Maintenance Manual

Transportation and Storage

V. Transportation and Storage

The pump can be transported and stored in both horizontal and vertical
position.
Never lift the pump by the motor cable. Always use the lifting shackle.
In case of long storage, the pump must be protected against moisture and
heat.

Before storing the pump, clean
it with a water jet and check the
motor housing for water ingress
(see Motor Housing under Routine
Maintenance section
). Every three
months, turn the impeller by hand.
This is necessary to prevent sticking
of the mechanical seal surfaces (see
Figure 12).
After 6 months of storage, a general
inspection is advised, before
installing the pump. Follow the
instructions of Section III: Start Up
Procedures
.

Figure 12

Hazardous pressure can

cause personal injury or

property damage.

CAUTION

WARNING

Wire rope WILL FAIL if worn-out, overloaded, misused,

damaged, improperly maintained or abused.

Wire rope failure may cause serious injury or death!
Protect yourself and others:
• ALWAYS INSPECT wire rope for, WEAR, DAMAGE or

ABUSE BEFORE USE.

• NEVER USE wire rope that is WORN-OUT, DAMAGED

or ABUSED.

• NEVER OVERLOAD a wire rope.

• INFORM YOURSELF: Read and understand

manufacturer’s literature or “Wire Rope and Wire

Rope Sling Safety Bulletin”.*

• REFER TO APPLICABLE CODES, STANDARDS and

REGULATIONS for INSPECTION REQUIREMENTS and

REMOVAL CRITERIA.*

* For additional information or the BULLETIN, ask your

employer or wire rope supplier.

© 1993, Wire Rope Technical Board

Form No. 193

Advertising