VII. Trouble Shooting

Safety

When working on the motor, make sure that the power is switched off. When working on

the pump make sure it cannot start unexpectedly. Only qualified electricians may do the

electrical work. When starting the pump ensure nobody goes near rotating parts.

PROBLEM

POSSIBLE CAUSE

REQUIRED ACTION CHECK POINTS

No voltage on

Check power supply

*No power

motor terminals

*Main isolator switch

*Fuses

Check motor

*Earth leakage relay

protection

*Motor protection relay

Pump

*Motor temperature

does not

*Water detector

start

Check start and

*Too low water level

stop signals

*Obstructed level switches

*Switches interchanged

*Control panel

Motor failure

Check motor

*Continuity and isolation

wiring

*Phase resistance

No stop signal

Check level

*Float switches

Pump

regulation

*Control panel

does not

Wrong start and

Check level

*Obstructed level switches

stop

stop level

regulation

*Adjust start and stop level

*Power supply not stable

Fault in power

Check power

*Low voltage

supply

supply

*Not all 3 phases available

Pump

*Setting of motor protection

starts and

Motor overloaded

Check pump

*Wrong direction of rotation

stops

*Impeller blocked

repeatedly

*Protection in automatic reset mode

Motor overheated

Check cooling

*Continuity and isolation

Check motor

*Fuses

Fault in power

Check power

*Low voltage

Current

supply

supply

*Impeller blocked

too high

Pump failure

Check pump

*Visc. or spec. gravity too high

*Wrong direction of rotation

Clogging or air lock Check discharge

*Discharge obstructed

and coupling

*Valve fully or partly closed

*Air pocket in pump or discharge

Pump runs

*Coupling leaks

but no flow or Pump failure

Check pump

*Impeller or volute blocked

too low flow

*Pump is sucking to much air

*Worn or broken impeller

Fault in power

Check power

*Control panel

supply

supply

*Fuses

*Low voltage

Trouble Shooting