SEASonAl SErvICE
• To REMOVE pump from service, remove drain plug and

drain all unprotected piping.

• To RETURN pump to service, replace drain plug using

Teflon™ tape or equivalent on male threads.

• Reconnect suction line if removed, examine union and repair

if necessary.

• Refer to OPERATION section of manual.

Disassembly

• Follow ALL warnings and instructions in the “MAINTE-

NANCE” section of this manual.

• Close-coupled units: Remove motor hold-down bolts.
• Frame-mounted units: Remove coupling guard, spacer, cou-

pling and frame hold-down bolts.

lIqUID EnD
1. Remove casing bolts (13).
. Remove back pull-out assembly from casing (1).
3. Remove casing wear ring (4) if excessively worn.
NOTICE: DO NOT INSERT SCREWDRIVER BETWEEN

IMPELLER VANES TO PREVENT ROTATION.

4. On close-coupled units, remove motor end plug or cover

to expose screwdriver slot or flats on end of motor shaft.

5. While restraining shaft with an appropriate tool (close-

coupled units) or with a strap wrench (frame-mounted

units) remove impeller bolt (6). Impeller bolt may need

to be heated with torch to remove. Discard.

NOTICE: EXERCISE CAUTION WHEN HANDLING

HOT IMPELLER BOLT.

NOTICE: FOR SAE DRIVE UNITS, REMOVE IMPELLER

NUT SET SCREW (A) PRIOR TO

REMOVING IMPELLER NUT (). IMPELLER

SET SCREW AND IMPELLER NUT MAY NEED

TO BE HEATED TO BE REMOVED.

6. Remove impeller washer (7).
7. Insert two pry bars, 180° apart, between impeller () and

seal housing (3). CAREFULLY pry off impeller.

8. Remove impeller key (8).
9. Remove seal housing bolts (14) and seal housing (3)

pulling with it the mechanical seal assembly. Discard seal

assembly and seal housing o-ring (9). For packed box

pumps see “PACKED BOX INSTRUCTIONS”.

10. Remove adapter (108).
11. Inspect shaft sleeve (11). If badly scored, remove by

heating with torch. Discard.

1. Push out the mechanical seal stationary seat from the

seal housing. Discard.

13. On units equipped, remove seal housing wear ring (5)

if excessively worn.

DISASSEmBly of BEArInG frAmE or

SAE BEArInG frAmE
1. Remove deflector (13) from shaft.
. Remove bearing cover (134).
3. Remove shaft assembly from frame.
4. Remove lip seals (138, 139) from bearing frame (8) and

bearing cover (134) if worn. Discard.

5. Remove retaining ring (361).
6. Use bearing puller or arbor press to remove ball

bearings (11, 168).

Reassembly

• All parts should be cleaned before assembly.
NOTICE: O-RING SHOULD BE REPLACED AFTER ANY

DISASSEMBLY OF UNIT.

BEArInG frAmE
1. Replace lip seals if removed.
. Replace ball bearings if loose, rough or noisy when rotated.
3. Check shaft (1) for runout. Maximum permissible is

0.00" (0.05 mm) TIR.

4. Refer to the “MAINTENANCE” section of this manual

for M-group bearing frame regreasing instructions.

lIqUID EnD
1. Inspect shaft removing any debris or burrs.
. Treat shaft with LOCQUIC

®

Primer “T”, or equivalent,

following manufacturer’s instructions carefully.

3. When replacing shaft sleeve, spray new shaft sleeve’s bore

with LOCQUIC

®

Primer “T”, or equivalent. Let parts dry

and then apply LOCTITE

®

#6 on the same surfaces.

Slide new sleeve over shaft with a twisting motion, wipe

off excess. Let cure according to instructions.

NOTICE: MECHANICAL SEAL MUST BE REPLACED

WHENEVER SEAL HAS BEEN REMOVED.

FOLLOW SEAL MANUFACTURER’S

INSTRUCTIONS CAREFULLY. FOR PACKED

BOX PUMPS SEE “PACKED BOX

INSTRUCTIONS”.

4. Replace seal housing wear ring, if removed.
5. For mechanical seal pumps, stationary seal seat may be

dipped in water to ease installation. Place stationary seal

seat squarely into seal housing bore. Cover the polished

face of the seat with a thin piece of cardboard or paper

towel. Press seat firmly into bore using a round piece of

plastic or wood that disperses the force over the entire

seal face. NOTE: If mechanical seal is supplied with a

spring retainer, remove and discard the retainer.

6. Place adapter, concave face pointing up, over motor

shaft and lower it onto the motor.

7. Replace seal housing o-ring. This o-ring may be lubricated

with water or glycerin to ease in installation. Install seal

housing on adapter. Exercise care in that the motor shaft

does not dislodge or damage seal seat.

8. Fully and squarely install the rotary assembly of seal

against the stationary seat.

NOTICE: REPLACE IMPELLER BOLT AND WASHER

WHENEVER IMPELLER IS REMOVED.

9. Install impeller key in shaft keyway. Mount impeller on

shaft and push until it bottoms. Hold in place. For SAE

units, apply LOCTITE 71 to the impeller bore, keyway

and shaft. Mount impeller on shaft and push until it

bottoms. Hold in place.

10. Install new impeller washer. Impeller washer not used for

SAE units..