Potassium compens.

(only with the setting

AmmoLyt+K: hide)

Automatic / Manual
1 ... 1000 mg/l

Automatic

(with a potassium electrode mounted):
When the potassium electrode is
mounted, the potassium compensation
takes places automatically only. The value
of the potassium concentration measured
at the time the setting table was opened is
displayed in the next line.

Manual

(without any potassium electrode
mounted):
After determining the potassium content of
the test solution enter the determined
potassium content manually in the next
line.
The measured value is accordingly
corrected by the entered potassium
content

Note: Detailed information on the subject
of potassium compensation is given in the
YSI primer, I

ON

SELECTIVE

MEASUREMENT

IN

ONLINE

ANALYSIS

.

Potassium conc.

(only with setting

AmmoLyt+K: hide)

1 ... 1000 mg/l

With Potassium compens.: Automatic:

Display of the potassium measured value.
With Potassium compens.: Manual:

Entry of the K value