Xylem FL16 WATER FLOW LOGGERS User Manual

Page 5

Advertising
background image

Global Water

800-876-1172

globalw.com

- 5 -

Level Sensor:


Sensor Element:

Silicone Diaphragm, Wet/Wet Transducer

Range:

Level:

0-3

feet

Temperature:

32°-122°F

(0°-50°C)

Linearity and Hysteresis: ±0.1% FS
Accuracy:

Level: ±0.1% FS at constant temperature

±0.2% over 32° to 70°F range

Temperature: Smaller of 0.5°F or ±1% of reading

Overpressure:

2 x full scale

Burst Pressure:

10 x full scale

Resolution:

Infinite

(Analog)

Outputs:

4-20mA ±1mA at full scale

Optional Temperature: 0-10mA ±1mA FS

Supply Voltage:

10-36VDC

Current Draw:

Sum of sensor outputs.

Warm Up Time:

10mS Min, 3 sec. recommended

Operating Temperature: 0° (Not Frozen) to +185°F
Compensated Range:

32° to 70°F submerged, automatic barometric
compensation


Sensor Housing:


Material:

316

SS

Size:

9”

long

x

1.0”

diameter

Weight: 250g

(9oz)


Cable:

Conductors:

4 each 22 AWG

Jacket Material:

87A shore hardness Polyurethane

Optional jacket:

Fluorinated Ethylene Propylene (FEP) Teflon

Cable O.D.:

7.8mm (0.307”)

Vent

tube:

HD

Polyethylene

Shield:

Aluminum

Mylar

Temperature range:

-30 to 85°C (-22 to 185°F)

Weight:

~65g/m

(0.7

oz/ft)