Xylem System 5000 User Manual User Manual

Page 105

Advertising
background image

103

General Setup

System 500

0

If None is selected, all Tasks will

be run regardless of the measured

battery voltage level. If the second

option is selected, Tasks will only be

run when the voltage level is within

the given range. If the voltage level

is outside of the specified range,

the system will simply schedule the

next scan and re-measure when

that time arrives.

GOES Radio

battery voltage level. If the second option is selected, GOES Transmissions will only be

scheduled and run when the voltage level is within the given range. If the voltage level is

outside of the specified range, the system will skip the current transmission scheduling and

re-measure on the next scan. Note that some GOES Radios have a built-in cut-off voltage

independent of this check.

Cut-off Temperature

Allows a minimum and maximum temperature range that must be met to continue normal

operation. If None is selected, all Tasks will be run regardless of the measured temperature. If the

second option is selected, Tasks will only be run when the measured temperature is within the

given range. If the temperature is outside of the specified range, the system will simply schedule

the next scan and re-measure when that time arrives. The temperature is retrieved and checked

at the beginning of each scan period.

If None is selected, all GOES

Transmissions will be scheduled

and run regardless of the measured

Advertising