Appendix

Base unit

Display

Type:

5.7", 1/4 VGA (320 x 240 pixels), TFT, color

LED back light, with touch screen

User Interface:

Graphical, with built in help menus.

Graphical user interface also accessible remotely

via Ethernet, Serial or USB ports.

Speaker:

Internal, for touchscreen key click and user interface

Push-to-read:

Pushbutton allows viewing measurement data without

opening the cover.

real Time Clock

Accuracy: 3.5ppm from -40° to +85°C
Battery:

Replaceable lithium cell

General

Processor:

32-bit, 192-MHz, ARM-9

SDRAM:

64-Mbytes

Operating System: LINUX

Data storage

Data Logging:

1Gbyte, expandable to 4Gbytes

Removable:

Multi-Media \ Secure Digital (SD) Card,

(32Mbyte to 4Gbyte cards available)

Format:

Microsoft™ FAT file system

Interface

USB Host:

Two (2) ports, full-speed (works with a thumb drive)

USB Device:

One port, full-speed (appears as a mass storage

device)
Ethernet: RJ-45 10/100Base-T, IEEE 802.3
RS-232:

Two (2) ports, 115.2Kbps, DB9, DTE, auto wake up

SDI-12:

Two (2) ea, 3-pin connectors, 1200 baud

(Master

mode)

+5V excitation Output

Type:

Switched, programmable “warmup” time

Voltage:

5.00V, ratio metric with A/D

Accuracy: ± 1.0 mV over load and temperature range
Current:

10mA max load

switched +12 Output

Voltage:

Depends on battery voltage

Current:

1A max, protected with polyfuse

4-20 ma Output

Type:

2-wire, loop powered, optically isolated

Resolution: 16-bits
Loop Voltage:

5.5V min, 35V max

Digital I/O

Channels:

Four (4) channels, independently configured for input

or

output.

Internal 47K pullup resistor to 5.0V

Voltage:

0-5V (input & output)

Input Type:

Schmitt, hysteresis: 0.7V min, 1.1V max

Input Voltage

Positive going: 2.6V min, 3.3V max

Negative going: 1.8V min, 1.1V max
Output Voltage:

Low: 0.5V max @ 24mA

High: 3.8V min @ -24mA

event, Frequency, Quadrataure Input

Type:

4-inputs, switch closure or voltage pulse

Programmable rising or falling edge triggered

Minimum Pulse Width:

5 mS (event & quadrature)

Input Frequency: 16 KHz max
Counter resolution: 32-bit

Quadrataure Output

Type:

Synthesized quadrature encoder, 2-encoders

Outputs: 2-wire/encoder, 0-5V, 64Hz step rate

aC Frequency Input

Type:

mV wind speed, dedicated input

Input Range:

1 to 10 KHz at ± 75mVolts or greater 1 to

15 KHz at ± 1 Volt or greater

Input Amplitude: ± 5.0 V Max
Accuracy: ± 0.1%
Resolution:

1/10000 * Reading

analog Input

Channels:

Four (4) single ended or two (2) differential

(each channel programable)

Resolution: 24-bit
Accuracy: ±0.05% FS
Input Range:

0 to 5 Volts (has built in transient protection)

GOes radio

Works with external H-2221 GOES transmitter via RS-232 port or H5000+
with built in H-2221 transmitter (see H-2221 specification for details).

Power

Input Voltage:

10.0 to 16.0 volts DC

Input Current:

Sleep:

6mA typical

Active: 80 mA typ (measuring, display off)

Active: 230 mA typ (measuring, display on)

Auto display shut-off after 3 minutes

mechanical

Enclosure:

Corrosion resistant fiberglass with clear Lexan®

window
Size:

9.0 in. wide x 10.5 in. long x 6.3 in. deep

Weight:

5.75 lbs (no option cards)

Mounting:

Hardware supplied for wall mounting

Expansion Slots:

3 slots

Connectors:

Plug-in terminal strips (included)

environment

Operating Range: -40° to +60° C
Storage Temperature:

-60° to +80° C

Humidity:

0-95% non-condensing

warranty

The WATERLOG® H-5000™ is warranted against defects in materials
and workmanship for one year from date of shipment.