7. Impeller
14. Shaft sleeve
Figure 2: Size A
1
2
3
4
5
6
7
8
9
10
11
12
13
14
4
1. Shaft
8. Volute
2. Slinger
9. Impeller locknut
3. Bracket coverplate
10. Gauge tapping
4. Volute capscrew
11. Suction
5. Discharge
12. Volute gasket
6. Companion flange
13. Seal assembly
7. Impeller
14. Shaft sleeve
Figure 3: Size AA
2. Measure the diameter of the shaft sleeve in order to determine nominal seal size.
There are three nominal seal sizes:
• 0.50 in. (1.27 cm)
• 0.75 in. (1.91 cm)
• 1.25 in. (3.16 cm)
Remove the seal assembly
1. Remove the motor assembly from the system.
2. Use either a strap wrench or a rag in order to prevent the impeller from turning with
one hand while you loosen the impeller nut with the other hand.
3. For all except the 1.25 in. (3.16 cm) seal assembly, lift the spring retainer and the seal
spring from the shaft.
4. Remove the compression ring from the seal collar by inserting a small screwdriver
underneath the ring and carefully applying an upward force.