background image

7. Impeller

14. Shaft sleeve

Figure 2: Size A

1

2

3

4

5

6

7

8

9

10

11

12

13

14

4

1. Shaft

8. Volute

2. Slinger

9. Impeller locknut

3. Bracket coverplate

10. Gauge tapping

4. Volute capscrew

11. Suction

5. Discharge

12. Volute gasket

6. Companion flange

13. Seal assembly

7. Impeller

14. Shaft sleeve

Figure 3: Size AA

2. Measure the diameter of the shaft sleeve in order to determine nominal seal size.

There are three nominal seal sizes:
• 0.50 in. (1.27 cm)
• 0.75 in. (1.91 cm)
• 1.25 in. (3.16 cm)

Remove the seal assembly

1. Remove the motor assembly from the system.
2. Use either a strap wrench or a rag in order to prevent the impeller from turning with

one hand while you loosen the impeller nut with the other hand.

3. For all except the 1.25 in. (3.16 cm) seal assembly, lift the spring retainer and the seal

spring from the shaft.

4. Remove the compression ring from the seal collar by inserting a small screwdriver

underneath the ring and carefully applying an upward force.