Warning, Caution, Description – Xylem P81630E Series VSC and VSCS Base Mounted Centrifugal Pumps User Manual

Page 2: Pump application, Operational limits, Safety instruction

Advertising
background image

DESCRIPTION

The VSC and VSCS Series centrifugal pumps are frame mounted

pumps which feature – high efficiency, rugged construction,

compact design, foot mounted volute, center drop out coupler,

and regreasable bearings. These features along with the verti-

cally split case make installation, operation, and service easy to

perform.

PUMP APPLICATION

The standard VSC and VSCS Series centrifugal pump’s bronze

fitted construction make it ideal for service with the following

liquids: unheated domestic and fresh water, boiler feed water,

condensate, hydronic cooling or heating, pressure boosting,

general pumping and benign liquids.
For other applications contact your local B&G Representative.

OPERATIONAL LIMITS

Unless special provisions have been made for your pump by

Bell & Gossett, the operational limits for VSC/VSCS Series

Pumps are as follows:
Maximum Working Pressure

Listed on pump nameplate.
SEAL OPERATING LIMITS
Standard Seals

BUNA-PH Limitations 7-9; Temperature Range -40 to +225°F

EPT-PH Limitations 7-11; Temperature Range -40 to +250°F

For use on closed or open systems which are relatively free of

dirt and/or other abrasive particles.
Flushed Single Seals

PH Limitations 7-9; Temperature Range 0 to +250°F†

Note: On closed or open low pressure systems which may

contain a high concentration of abrasives an external flush is

required.

Flushed Double Seals

PH Limitations 7-9; Temperature Range 0 to +250°F

Note: On closed or open low pressure systems which may

contain a high concentration of abrasives an external flush is

required.
Packing

PH Limitations 7-9; Temperature Range 0 to +200°F

Note: On open or closed systems which require a large

amount of makeup water, as well as systems which are sub-

jected to widely varying chemical conditions and solids buildup.

† For operating temperatures above 250°F a cooled flush is required

and is recommended for temperatures above 225°F for optimum seal

life. On closed systems cooling is accomplished by inserting a small

heat exchanger in the flush line to cool the seal flushing fluid.
Flush-line Filters and Sediment Separators are available on special

request.

2

SAFETY

INSTRUCTION

This safety alert symbol will be used in this manual and on the

pump safety Instruction decal to draw attention to safety related

instructions. When used, the safety alert symbol means

ATTENTION! BECOME ALERT! YOUR SAFETY IS INVOLVED!

FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN

A SAFETY HAZARD.
Your VSC/VSCS Series Pump should have the following safety

instruction decals located approximately as shown. If the

decals are missing or illegible contact your local B&G repre-

sentative for a replacement.

WARNING

ROTATING COMPONENTS

DISCONNECT AND LOCK OUT

POWER BEFORE SERVICING.

DO NOT OPERATE WITHOUT

ALL GUARDS IN PLACE.

CONSULT INSTALLATION

AND SERVICE INSTRUCTION

SHEET BEFORE OPERATING

OR SERVICING.

FAILURE TO FOLLOW

INSTRUCTIONS COULD

RESULT IN INJURY

OR DEATH.

P70642

WARNING

EYEBOLTS OR LIFTING

LUGS IF PROVIDED ARE

FOR LIFTING ONLY THE

COMPONENTS TO WHICH

THEY ARE ATTACHED.

FAILURE TO FOLLOW

INSTRUCTIONS COULD

RESULT IN INJURY

OR DEATH.

P70643

CAUTION

DO NOT RUN PUMP DRY,

SEAL DAMAGE MAY OCCUR.

INSPECT PUMP SEAL

REGULARLY FOR LEAKS,

REPLACE AS REQUIRED.

FOR LUBRICATION

REQUIREMENTS, CONSULT

SERVICE INSTRUCTIONS.

FAILURE TO FOLLOW

INSTRUCTIONS COULD

RESULT IN INJURY OR

PROPERTY DAMAGE.

P70644

CAUTION

COUPLER ALIGNMENT IS

REQUIRED! LEVEL AND GROUT

PUMP BEFORE USE!

CHECK ALIGNMENT BEFORE

GROUTING, AFTER SYSTEM IS

FILLED, AFTER SERVICING

PUMP, AND AS REQUIRED.

CONSULT THE SERVICE

INSTRUCTIONS FOR DETAILS.

FAILURE TO FOLLOW THESE

INSTRUCTIONS COULD

RESULT IN INJURY OR

PROPERTY DAMAGE.

P70820

ALTERNATE

LOCATION

(2) REQUIRED

(1 EACH SIDE)

Advertising