Product description, General description, Operational specifications – Xylem P81673H Series 1510 User Manual

Page 13: General description operational specifications

Advertising
background image

Product Description

General description

Description

The pump is a centrifugal, frame-mounted pump. The following pump features make it
easy to install, operate, and service:

• High efficiency
• Rugged bronze-fitted construction
• Foot-mounted volute with back pullout bearing frame
• Center drop-out coupler
• Regreasable bearings

Intended applications

WARNING:
California Proposition 65 warning! This product contains chemicals known to the state of
California to cause cancer and birth defects or other reproductive harm.

The pump is intended for use with these pumped fluids:

• Unheated domestic and fresh water
• Boiler feed water
• Condensate
• Hydronic cooling or heating
• Benign liquids
• Pressure boosting
• General liquid transfer

Rotation

Pump rotation is clockwise when viewed from the back of the motor. An arrow is also
located on the pump to show the direction of rotation.

Operational specifications

Mechanical seal specifications

This table describes the specifications of each mechanical seal type.

Seal type

Parameter

Value

Standard seals, BUNA

pH range limits for BUNA

pH 7–9

Liquid temperature range that

complies with the pH range limits for

BUNA

-20˚F to 225˚F (-29˚C to 107˚C)

Standard seals, EPT

pH range limits for EPT

pH 7–11

Liquid temperature range that

complies with the pH range limits for

EPT

-20˚F to 250˚F (-29˚C to 121˚C)

Flushed single seals

1,3,4

pH range limits

pH 7–9

Liquid temperature range

0˚F to 250˚F (-18˚C to 121˚C)

Product Description

Series 1510 Installation, Operation, and Maintenance Manual

11