Parallel

Angular

1

2

3

1.

Sizes E2 - E10

2.

Sizes E20 - E50

3.

Sizes E60 - E80

Fastener torque values and maximum RPM for Rexnord Omega couplings

Basic size (see

element)

Element and ring

capscrew torque ft-lbs

(Nm)

Standard hubs set

screw torque ft-lbs

(Nm)

Maximum rpm
Standard

Spacer

E2

17 (2)

7 (1)

7500

7500

E3

7 (1)

7500

7500

E4

14 (2)

7500

7500

E5

23 (3)

7500

7500

E10

23 (3)

7500

7500

E20

30 (3)

50 (6)

6600

4800

E30

50 (6)

5800

4200

E40

100 (11)

5000

3600

E50

100 (11)

4200

3100

E60

75 (8)

167 (19)

3800

2800

E70

167 (19)

3600

2600

E80

167 (19)

2000

1800

Final alignment

You cannot perform the final alignment until you initially operate the pump long enough to
reach operating temperature. When the pump reaches the normal operating temperature,
then secure the pump and re-check the alignment. Make sure that you compensate for
temperature accordingly.