Micro-flo, 0 features, 0 model number matrix – Xylem MICROFLO PADDLEWHEEL FLOWMETERS User Manual

Page 3

Advertising
background image

2.0 Features

!

Four connection options available:

1/8” F/NPT, 1/4” F/NPT, 1/4” OD x .170 ID Tubing & 3/8” OD x 1/4”
ID Tubing sizes.

! Six body size/flow range options available:

30 to 300 ml/min, 100 to 1000 ml/min, 200 to 2000 ml/min,
300 to 3000 ml/min, 500 to 5000 ml/min, 700 to 7000 ml/min.

! 3 model display variations:

FS = Sensor mounted display
FP = Panel mounted display (includes 6’ cable)
FV = No display. Sensor only. 5vdc current sinking output

! 6 digit LCD, up to 4 decimal positions.

! Displays both rate of flow and total accumulated flow.

! Open collector alarm setpoint.
! User selectable or custom programmable K-factor.

Flow units: Gallons, Liters, Ounces, milliliters

Time units: Minutes, Hours, Days

! Volumetric field calibration programming system.

! Non-volatile programming and accumulated flow memory.

! Total reset function can be disabled.

! Clear PVC viewing lens or PVDF chemical resistant lens.

! Weather resistant Valox PBT enclosure. NEMA 4X

Page 3

MICRO-FLO

METER FUNCTION

FS = Flow rate and Totalizing. On-sensor mounting
FP = Flow rate and Totalizing. Remote panel mounting
FV = Flow sensor only (no display)

POWER SUPPLY

1 = Transformer U.S. 115VAC/15VDC
2 = Transformer E.U. 220VAC/15VDC
3 = Transformer U.S. 230VAC/15VDC
None = No selection (customer supplied)

FLOW RANGE SELECTION

10 = 30-300 ml/min
20 = 100-1000 ml/min
30 = 200-2000 ml/min
40 = 300-3000 ml/min
50 = 500-5000 ml/min
60 = 700-7000 ml/min

O-RING SEAL

V = Viton
E = EPDM

CONNECTOR

4 = .250” OD tubing PVDF
5 = .125” Female NPT PVC
6 = .375” OD tubing PVDF
7 = .250” Female NPT PVC

LENS MATERIAL

0 = Clear PVC
1 = Opaque PVDF

3.0 Model number matrix

Advertising