Extron Electronics DVI 201xi Tx User Guide User Manual

Page 18

Advertising
background image

6.

Boot up the source device. The source boots with the resolution and refresh rate of the
local monitor.

7.

Power on the display device.

NOTE: The remote display device must be capable of handling a resolution equal to

or greater than that of the local monitor.

Using Pass-through Mode with DDC Routed to the Remote Display

NOTE: Although DDC can be routed to the remote display, there may be instances

when the signals may become corrupted or weak. In those cases, the source
device may be unable to boot up correctly.

1.

Set the EDID Minder switch to the Off (Down) position and the Remote DDC switch to
the On (Up) position (see the figure at right). The position of the Default
EDID switch is not relevant.

2.

Connect the source device to the transmitter input.

3.

Connect the display device to the receiver output and, if required, the local
monitor to the transmitter output.

4.

Connect the transmitter to the receiver with the two twisted pair cables.

z

z

Transmitter port 1 connects to receiver port 1

z

z

Transmitter port 2 connects to receiver port 2

5.

Power on the remote display.

6.

Boot up the source device. The source boots with the resolution and refresh rate of the
remote display.

NOTE: The local monitor is the source of EDID and must be powered on before the

source device is booted.

7.

Power on the display device.

NOTE: If used, the local monitor must be capable of handling a resolution equal to

or greater than that of the remote display.

ON

1 2 3

ON

OFF

DEF

AUL

T EDID

EDID MINDER

REMOTE DDC

DVI 201xi Tx • Configuration and Operation

12

Advertising