Programming
Guide
This section describes Simple Instruction Set operation of the GSS 100.
The rear panel RS-232 connector (see figure 16) can be connected to the serial port of a
host device, such as a computer or control system. Communications with the GSS are via the
Extron Simple Instruction Set (SIS).
5
1
9
6
RS-232 Function
Pin
1
2
3
4
5
6
7
8
9
—
Tx
Rx
—
Gnd
—
—
—
—
Not used
Transmit data
Receive data
Not used
Signal ground
Not used
Not used
Not used
Not used
RS-232
Figure 16.
Remote Connector Pinout
The baud rate for the rear panel RS-232 port can be set to a variety of different rates. The
default protocol for the port is as follows:
z
z
9600 baud
z
no parity
z
z
8-bit, 1 stop bit
z
no flow control
GSS 100 Graphic Still Store • Programming Guide