Front Panel Features
See figure 2 to identify the front panel features on the transmitter and receiver.
MTP RL 15HD A Receiver
M T P S E R I E S
MTP RL 15HD A SEQ Receiver
RGB
PEAKING
LEVEL
RGB
DELAY
PEAKING
LEVEL
MTP SERIES
RED
GREEN
ADJUST
BLUE
SELECT
ON
1 2 3 4 5
H SYNC
+
V SYNC
+
S-VIDEO
END UNIT
SP
ARE
ON
1 2 3 4 5
H SYNC
+
V SYNC
+
S-VIDEO
END UNIT
SP
ARE
MTP T 15HD A Transmitter
M T P S E R I E S
50 Hz
RECORD
60 Hz
SPARE
EDID
SELECT
ON
E
D
C
B
K
G
F
K
G
F
J
I
H
A
A
A
Figure 2.
MTP 15HD Front Panels
A
Power LED — The LED indicator lights when the unit is receiving power.
B
Record LED — The LED indicator flashes red during the EDID recording process to
indicate a new EDID being written to memory. The LED returns to a solid green after the
write completes.
C
Record button — The recessed record button is used to initiate recording of the
EDID of a display device (connected to the loop-through output) to user-programmable
memory position 0 on the rotary switch (
E
).
D
Vertical frequency DIP switch — The first DIP switch selects the vertical frequency
for the pre-programmed EDID. When switched to OFF (default position), the EDID
selected by the rotary positions 1 through E are based on 60 Hz. When switched to ON,
they are based on 50 Hz. The second DIP switch, marked SPARE, is not used.
NOTE: When the EDID select rotary switch (
E
) is in position 0 or F, the setting of
the first DIP switch is not applicable because the user-recorded or attached display
EDID is being used.
A
Power LED
B
Record LED
C
Record button
D
Vertical frequency DIP switch
E
EDID select rotary switch
F
Level control
G
Peaking control
H
Select button (SEQ model only)
I
Red, Green, and Blue LEDs
(SEQ model only)
J
Delay (skew adjustment) control
(SEQ model only)
K
DIP switches (RL receivers only)
MTP 15HD A Series • Installation and Operation