Rack Mounting Procedure

The unit can be mounted on optional rack systems, including:

z

RSU 129: 9.5 inch deep, 1U rack shelf kit (part number

60-190-01

)

z

RSU 126: 6 inch deep, 1U rack shelf kit (part number

60-190-10

)

To mount the device on a rack shelf

1.

Remove the feet from the bottom of the MTP, if they are installed.

2.

Mount the MTP using two 4-40 x 3/16 inch screws in opposite (diagonal) corners to
secure the MTP to the shelf.

NOTE: DO NOT stack units on top of one another as this may cause the units to

overheat.

3.

Install false faceplates or other units to the rack shelf.

Use 2 mounting holes on
opposite corners.

(2) 4-40 x 3/16"
Screws

NOTE:

Using screws longer

than 3/16” will damage the
unit and void the warranty.

1U Universal Rack Shelf

Front false
faceplate
uses 2
screws.

1/2 Rack Width Front False
Faceplate

Figure 9.

Mounting the MTP on a Standard Shelf

Under-desk Mounting

Mount the unit under a desk or podium, using the optional Extron MBU 125 under-desk
mounting kit (part number

70-077-01

) by following the instructions provided with the kit.

Through-desk Mounting

Mount the unit through a desk or podium using the optional Extron MBD 129 through desk
mounting kit (part number

70-077-02

) by following the instructions provided with the kit.

MTP 1500RL 15HD A SEQ • Mounting