Extron Electronics VN-Matrix 200 Series User Manual
Page 117

Serial Port Login Procedure
1.
From the Login: prompt, type
config
followed by the <Enter> key.
2.
When prompted for a password, type
config
followed by the <Enter> key.
The following menu will then appear.
Network Port 1
Network Port 2
==============
==============
0.
Speed/Duplex: auto_10_100_1000
10. Speed/Duplex: auto_10_100_1000
1. Boot method: static [dhcp]
11. Boot method: static [dhcp]
2. address: 192.168.0.1
12. address: 192.168.1.1
3. netmask: 255.255.255.0
13. netmask: 255.255.255.0
4.
gateway: 192.168.0.1
14
Gateway: 192.168.0.1
5. broadcast:
15. broadcast:
6.
mtu: 1500
16. mtu: 1500
7. controller ip: 192.168.0.18
17. ip forwarding: 0
8. controller port: 5432
18. webserver port: 80
9. Exit
3.
Type the menu option number required followed by the <Enter> key.
4.
Where required, type the new value followed by the <Enter> key.
5.
To exit the menu and return to the main command prompt, type
9
followed by the
<Enter> key.
Command options
The following commands are also supported from the main command prompt:
Exit
To logout from the session
Reboot
To force the VN 200 device to restart
Ping
To test network communications with another device (see
“
Understanding Network Performance
”)
VN-Matrix 200 Series • Technical Data