OM−04417

SM SERIES

PAGE B − 6

INSTALLATION

NOTE

Refer to the performance curve in the Parts List
Manual when determining the most efficient piping
installation.

Table B-3. MSHA Specifications And Approval Data

MSHA Approval Number (All Models)

2G−3971A−0

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Commonwealth of Pennsylvania Approval Number (Only Models With *)

BFE−637−77

. . . . . . . . .

Model

MSHA No.

Motor

G-R P/N

Trailing Cable

Motor Cable

*SM2E1-X3.5 460/3
*SM2E1-X3.5 575/3
*SM2E18-X3.5 460/3
*SM2E18-X3.5 575/3
*SM2E65-X3.5 *460/3
*SM2E65-X3.5 575/3

XP−3142−0
XP−3142−0
XP−3142−1
XP−3142−1
XP−3142−1
XP−3142−1

47111−100
47111−101
47111−070
47111−071
47111−068
47111−069

No. 8, 3 Conductor,
Type G-GC, .97"

$

.03" O.D., Protected By
An Instantaneous Trip
Circuit Breaker, Set At
200 Amps Max., MSHA
Flame Resistance,
600/2000 Volt, 90

_C.

Max. Length: 500 Ft. -
Customer Furnished

P-122-MSHA. G-R P/N
47351−011. #12 AWG,
7 Conductor Type SPC,
0.89"

$ 0.03" O.D.,

Heavy Jacketed 90

_C

600/2000 Volt Royal -
MSHA 122., Flame Re-
sistant, Max. Cable
Length 500 Ft.

SM2F1-X1 460/3
SM2F1-X1 575/3

XP−3862−0
XP−3862−0

16368
16368

No. 8, 3 Conductor,
Type G-GC, .97"

$

.03" O.D., Protected By
An Instantaneous Trip
Circuit Breaker, Set At
200 Amps Max., MSHA
Flame Resistance,
600/2000 Volt, 90

_C.

Max. Length: 500 Ft. -
Customer Furnished

P-122-MSHA. G-R P/N
47351−011. #12 AWG,
7 Conductor Type SPC,
0.89"

" 0.03" O.D.,

Heavy Jacketed 90

_C

600/2000 Volt Royal -
MSHA 122., Flame Re-
sistant, Max. Cable
Length 500 Ft.

*SM3B1-X6 460/3
*SM3B1-X6 575/3
*SM3B18-X6 460/3
*SM3B18-X6 575/3
*SM3B65-X6 460/3
*SM3B65-X6 575/3

XP−3185−0
XP−3185−0
XP−3185−1
XP−3185−1
XP−3185−1
XP−3185−1

47111−104
47111−105
47111−082
47111−083
47111−086
47111−087

No. 8, 3 Conductor,
Type G-GC, .97"

$

.03" O.D., Protected By
An Instantaneous Trip
Circuit Breaker, Set At
200 Amps Max., MSHA
Flame Resistance,
600/2000 Volt, 90

_C.

Max. Length: 500 Ft. -
Customer Furnished

P-122-MSHA. G-R P/N
47351−011. #12 AWG,
7 Conductor Type SPC,
0.89"

" 0.03" O.D.,

Heavy Jacketed 90

_C

600/2000 Volt Royal -
MSHA 122., Flame Re-
sistant, Max. Cable
Length 500 Ft.

*SM3C1-X6 460/3
*SM3C1-X6 575/3
*SM3C18-X6 460/3
*SM3C18-X6 575/3
*SM3C65-X6 460/3
*SM3C65-X6 575/3

XP−3185−0
XP−3185−0
XP−3185−1
XP−3185−1
XP−3185−1
XP−3185−1

47111−106
47111−107
47111−084
47111−085
47111−088
47111−089

No. 8, 3 Conductor,
Type G-GC, .97"

$

.03" O.D., Protected By
An Instantaneous Trip
Circuit Breaker, Set At
200 Amps Max., MSHA
Flame Resistance,
600/2000 Volt, 90

_C.

Max. Length: 500 Ft. -
Customer Furnished

P-122-MSHA. G-R P/N
47351−011. #12 AWG,
7 Conductor Type SPC,
0.89"

" 0.03" O.D.,

Heavy Jacketed 90

_C

600/2000 Volt Royal -
MSHA 122., Flame Re-
sistant, Max. Cable
Length 500 Ft.