OM−04417

SM SERIES

PAGE B − 13

INSTALLATION

ROCK

8 FEET
(2,4 M)

3/4 INCH (19,1

MM) NOMINAL

DIAMETER

(MINIMUM)

SOIL

SOIL

SOIL

1/4 INCH STEEL

PLATE 2 SQ. FEET

(1858,1 SQ. CM)

SURFACE AREA

(MINIMUM)

a) PLATE ELECTRODE

b) DRIVEN ELECTRODE

c) BURIED ELECTRODE

3/4 INCH (19,1 MM)

NOMINAL DIAMETER

(MINIMUM) 8 FEET

(2,4 M) LONG

Figure B-2. Suggested Grounding Methods

a. Plate Electrode: An iron or steel plate, 1/4

inch (6,4 mm) thick, completely impeded in
the ground. The plate must present a surface
area of at least 2 square feet (1858,1 sq. cm).

b. Driven Electrode: A rod or pipe, 3/4 inch

(19,1 mm) in diameter minimum, 8 feet (2,4 m)
long, completely driven into the ground.

c. Buried electrode: If rock or stone prevents

embedding the full 8 foot (2,4 m) length of the
ground rod, bury it horizontally in a trench.

Space the ground rod or plates at least 6 feet
(1,8 m) from any other electrode or ground
rod, such as those used for signal circuits, ra-
dio grounds, lightning rods, etc.

The earth surrounding the ground rod or plate
must contain enough moisture to make a
good electrical connection. In dry or sandy ar-
eas, pour water around the rod, or consult
qualified personnel to devise a method of im-
proving the connection.

The electrical power used to operate
this pump is high enough to cause inju-
ry or death. Make certain that the control
box is properly grounded after installa-
tion.

Refer to the literature accompanying the control
box for field wiring connections.

Pump Power Cable Connections

The electrical power used to operate
this pump is high enough to cause inju-
ry or death. Obtain the services of a qu-
alified electrician to make all electrical
connections. Make certain that incom-
ing power to the control box is in the off
position and locked out, or that the pow-
er supply to the control box has been
otherwise cut off and locked out, before
connecting power or accessory cables.

The standard pump is provided with a 50 foot
power cable (see Table B-5 for cable specifica-
tions). If a longer cable is required, an optional ca-
ble assembly must be ordered from the factory.
Splicing of the power cable is not recommended
by the Gorman-Rupp Company due to safety and
warranty considerations.

Never attempt to alter the length or re-
pair any power cable with a splice. The
pump motor and cable must be com-
pletely waterproof. Injury or death may
result from alterations.