Operation - section c – Gorman-Rupp Pumps SM4G1-X30 460/3 1002211 thru 1241783 User Manual

Page 21

Advertising
background image

SM SERIES

OM−04417

OPERATION

PAGE C − 1

OPERATION − SECTION C

Review all SAFETY information in Section A.

This pump is designed to handle most
non-volatile, non-flammable liquids en-
countered in mine dewatering. Do not
attempt to pump volatile, explosive, or
flammable materials, or any liquids
which may damage the pump or endan-
ger personnel as a result of pump fail-
ure.

Follow the instructions on all tags, labels and de-
cals attached to the pump.

Pump Performance

Any control box used to operate the
pump must be approved by the MSHA
and the Gorman-Rupp Company for the
application.

Refer to the pump Specification Data Sheet or the
accompanying Parts List Manual for the specific
performance for your pump.

Control Box

A control box is provided to facilitate operation of
the pump. It contains controls for starting and stop-
ping the pump, and provides overload protection
for the pump motor.

The pump is designed to be operated
through the control box furnished with
the pump. The control box provides

overload protection and power control.
Do not connect the pump motor directly
to the incoming power lines.

See the operating instructions furnished with the
control box before attempting to start the pump.

PUMP OPERATION

This pump is designed to handle most
non-volatile, non-flammable liquids en-
countered in mine dewatering. Do not
attempt to pump volatile, explosive, or
flammable materials, or any liquids
which may damage the pump or endan-
ger personnel as a result of pump fail-
ure.

Liquid Temperature And Overheating

The maximum liquid temperature for the pump is
120

_ F (49_ C). Do not apply the pump at higher

operating temperatures.

Approach the pump cautiously after it
has been running. Although the motor is
cooled by the liquid being pumped, nor-
mal operating temperatures can be high
enough to cause burns. The tempera-
ture will be especially high if operated
against a closed discharge valve. Never
operate against a closed discharge
valve for long periods of time.

If overheating does occur, stop the pump immedi-
ately and allow it to cool before servicing it. Ap-
proach any overheated pump cautiously.