Elmo Rietschle V-KTN 15/25/40 User Manual

Page 14

Advertising
background image

14

|

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

Bauj./Nr. 09

S1 5,50 / 6,50

kW

Typ KTR 100 (01)

+ 0,60 / - 0,60 bar

2843970

100 / 120 m³/h

EN 60034

1460 / 1745 min

-1

1027630137

3~

Mot.

Set up and operation

6

1

7

8

9

10

3

4

5

2

4.1.1 Data plate

1

Type/ Size (mechanical version)

2

Year of construction

3 Motor

design

4 Serial

number

5 Item

no.

6

Overpressure / Vacuum

7

Flow rate 50 Hz / 60 Hz

8 Speed

50

Hz / 60

Hz

9

Motor output 50 Hz / 60 Hz

10 Operating

mode

4.2 Description

The V-KTN range has a connecting thread on the pressure side and on the suction side. The aspirated air
is cleaned by an inbuilt fi ne micro fi lter. The carbon dust caused by the scoring of the blades can also be
separated by an integral fi lter.
The motor and the pump have a common shaft.
The V-KTN (01

➝ 06) and (08 ➝ 10) are in a plastic sound cover. Inside the sound cover is also a fan that

provides cooling. The vacuum regulating valve (Fig. 2/C) and the pressure regulating valve (Fig. 2/D) enable
the vacuum and pressure to be set to the required values which have an upper limit.
The compressed air is cooled by a cooling segment in versions (03), (06), (09) and (10).
The V-KTN (13) is located in a tin cover. It is cooled by the motor fan. The V-KTN (13) has a vacuum safety
valve on the suction side (Fig. 3/C

1

) and a pressure relief valve on the pressure side (Fig. 3/D

1

).

4.3. Areas of application

These dry running rotary vane pressure vacuum pumps models V-KTN 15 to V-KTN 40 are suitable for creat-
ing pressure and vacuum at the same time. Constant operation is permissible.

The nominal fl ow rate is 15, 25 and 40 m

3

/h at 50 Hz. The load limits (bars) on the intake and pressure sides

are specifi ed on the data plate (Fig. 2/N). Data sheet D 480 shows the dependency of the fl ow rate on the
excess pressures.

These dry running machines are suitable for conveying air with a relative humidity of 30 - 90 %.

If the unit is switched on more frequently (at regular intervals of about 10 times an hour) or at
higher ambient temperatures and intake temperatures, the excess temperature limit of the motor
winding and the bearings may be exceeded.
Please contact the manufacturer should the unit be used under such conditions.

If it is installed in the open air the unit must be protected from environmental infl uences, (e.g. by a
protective roof).

Advertising