Elmo Rietschle V-KTN 15/25/40 User Manual

Page 26

Advertising
background image

26

|

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Excess pressure or
vacuum not achieved

Machine or system leaking

Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated.

Section 7.2

Blades are worn or damaged

Replace blades

Section 7.2.2
Section 7.4

Machine gets too hot

Ambient or intake temperature
is too high

Ensure it is being used prop-
erly

Section 2.3

Cooling air supply is ob-
structed

Check environmental condi-
tions

Section 5.1

Clean ventilation slots

Section 7.2

The blow out fi lter cartridge is
dirty.

Clean or replace the fi lter
cartridge

Section 7.2.1
Section 7.4

The regulating valves are dirty
so that the permissible pres-
sure and / or vacuum values
have been exceeded.

Clean or replace the regulat-
ing valves

Section 7.2
Section 7.4

The machine makes
an abnormal noise

The compressor housing is
worn (chatter marks)

Repair by manufacturer or
authorised workshop

Elmo Rietschle
Service

A regulating valve is vibrating

Replace the valve

Section 7.4

Blades are damaged

Replace blades

Section 7.2.2
Section 7.4

Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.

Advertising