Elmo Rietschle V-KTN 15/25/40 User Manual

Page 16

Advertising
background image

16

|

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

Installation

5.3 Connecting

pipes

a) Vacuum connection at (Fig. 2/A) and pressure

connection at (Fig. 2/B).

NOTICE

Material damage resulting from the forces and
torques of the pipes on the unit being too high.
screw pipes in by hand.

The machine output is reduced if the pipes are
too narrow and/or too long.

b) Check to ensure the intake line and pressure line

are connected correctly.

NOTICE

Length of the connection pipes
With connection pipes that have the same pipe
cross section as the machine connection and are
more than 3m long, a non-return valve especially
for the purpose must be installed in order to avoid
reverse operation when the machine has stopped

5.4

Control and relief valves

The required pressure and vacuum ranges can be
set with the pressure regulating valve (Fig. 2/D) and
the vacuum regulating valve (Fig. 2/C) as shown on
the symbol plate attached to the rotary knob.

NOTICE

Do not operate without the standard control
and relief valves.
If the permissible fi nal compression pressure is
exceeded (see data plate) the machine may be
damaged.

Advertising