Maintenance and repair

s

G

b

s

s

f

m

C

h

m

D

k

o

e

1

2

Fig. 5 Air fi ltering

C

Vacuum regulating valve

D

Pressure regulating valve

G

Outlet grid

b Housing

lid

e, f,h Filter cartridge

k

Filter cover

m

Knurled knob

o

Knurled nut

s

Screw cap

7.2.1 Air fi ltering

NOTICE

Insuffi cient maintenance on the air fi lter
The power of the machine lessens and damage may
occur to the machine.

The fi lter cartridges (Fig. 5/e) for intake air, (Fig. 5/f)
for blowing air and (Fig. 5/h) for air charging must be
cleaned every month or more often depending on
how dirty they are by blowing out from inside to out-
side. In spite of cleaning the fi lters their separation
effi ciency will continue to deteriorate. Therefore the
fi lters should be replaced every six months.
Changing fi lters:
V-KTN (01

➝ 06) and (08 ➝ 10): Unscrew the outlet

grid (Fig. 5/G).
Undo the screw cap (Fig. 5/s) and the knurled knob
(Fig. 5/m). Undo the knurled nut (Fig. 5/o) and re-
move the fi lter cover (Fig. 5/k). Remove and clean or
replace fi lter cartridges (e), (f) and (h). Reassemble in
reverse order.

WARNING

Danger of injury when dealing with com-
pressed air.
When blowing through with compressed air, solid
particles may be carried along or powder dust swir-
ling around may cause injury to the eyes. Therefore,
when cleaning with compressed air always wear
goggles and a dust mask.

Fig. 6 Purging fi lter cartridge

1 Filter

cartridge

2

Compressed air

Advertising