Elmo Rietschle V-VGD 10/15 User Manual

Page 15

Advertising
background image

15

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Installation

5.3 Connecting

pipes

NOTICE

Material damage resulting from the forces and
torques of the pipes on the unit being too high.
Only screw pipes in by hand.

The pumping capacity of the vacuum pump
is reduced if the suction pipe is too narrow
and/or too long.

The air vent (Fig. 2/B) must not be closed or
restricted.

Counter pressures on the outlet side are only
permissible up to + 0.1 bars.

Prevent liquids accumulating in the exhaust
line.

a) The vacuum connection (Fig. 2/A) is on the angle

fl ange (Fig. 2/D).

b) The discharged air can be freely blown out

through the exhaust air hole (Fig. 2/B) or con-
ducted away using a hose or pipe.

5.4

Filling with lubricating oi

a) Fill the lubricating oil (for suitable types see the

„Maintenance“ section) via the oil fi lling point
(Fig. 2/H) up to the upper edge of the sight glass
(Fig. 2/I).

b) Close the oil fi lling point.

Advertising