Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Machine is switched
off by the motor pro-
tection switch

Mains voltage/ Frequency
does not correspond with the
motor data

Check by qualifi ed electrician

Section 5.5

Connection to motor terminal
board is not correct

Motor protection switch is not
set correctly

Motor protection switch is
triggered too quickly

Use a motor protection switch
with an overload-dependent
delayed switch off that takes
into consideration the short
term excess current at start
up (version with short circuit
and overload trigger as per
VDE 0660 Part 2 orIEC 947-4)

Vacuum pump or its oil is too
cold

Note the ambient temperature
and the intake temperature

Section 2.3

The lubricating oil is too vis-
cous

The oil viscosity must comply
with ISO VG 46 as per DIN
51519

Section 7.2.2

The oil separator element is
dirty.

Change the oil separator ele-
ment

Section 7.2.3

The back pressure is too high
when the exhaust air is being
discharged.

Check the hose or the pipe

Section 5.3

Pumping capacity is
insuffi cient

The suction pipe is too long or
too narrow

Check the hose or the pipe

Section 5.3

Leak on the suction side of
the vacuum pump or in the
system

Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated.

Section 7.2

The intake fi lter is dirty

Clean or replace the intake
fi lter

Section 7.2.1