Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Final pressure (max.
vacuum) is not
reached

Leak on the suction side of
the vacuum pump or in the
system

Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated.

Section 7.2

Incorrect oil viscosity

The oil viscosity must comply
with ISO VG 46 as per DIN
51519

Section 7.2.2

The adjustment bolt (X) is not
set correctly.

Set the operating range cor-
rectly.

Section 6.1.2

Machine gets too hot

Ambient or intake temperature
is too high

Ensure it is being used prop-
erly

Section 2.3

Cooling air supply is ob-
structed

Check environmental condi-
tions

Section 5.1

Clean ventilation slots

Section 7.2

The lubricating oil is too vis-
cous

The oil viscosity must comply
with ISO VG 46 as per DIN
51519

Section 7.2.2

The oil separator element is
dirty.

Change the oil separator ele-
ment

Section 7.2.3

The back pressure is too high
when the exhaust air is being
discharged.

Check the hose or the pipe

Section 5.3

Exhaust air contains
visible oil mist

The oil separator element is
not inserted correctly or the O
ring is missing

Check that it is correctly
seated

Section 7.2.3

Unsuitable oil is being used

Use suitable types

Section 7.2.2

The oil separator element is
dirty.

Change the oil separator ele-
ment

Section 7.2.3

The back pressure is too high
when the exhaust air is being
discharged.

Check the hose or the pipe

Section 5.3

Ambient or intake temperature
is too high

Ensure it is being used prop-
erly

Section 2.3

Cooling air supply is ob-
structed

Check environmental condi-
tions

Section 5.1

Clean ventilation slots

Section 7.2

Advertising