Technical Data

610.44434.40.000

10 / 32

© Gardner Denver Deutschland GmbH

Sound power level

Sound power level L

W

as per EN ISO 3744,

tolerance

3 dB (A).

Two-impeller design

Sound power level L

W

[dB (A)]

Type

50 Hz

60 Hz

2BH191. -

98

2BH1940 -

98

2BH1943 -

99

2BH923.. -

93



Tightening torques for screw connections

The following values apply if no other information
is available.
With non-electrical connections, property classes
of 8.8 and 8 or higher as per ISO 898-1 are
assumed.

Tightening torques for

non-electrical connections

Thread

[Nm]

[ft lbs]

M4

2.7 - 3.3

1.99 - 4.44

M5

3.6 - 4.4

2.65 - 3.25

M6

7.2 - 8.8

5.31 - 6.5

M8

21.6 - 26.4

15.9 - 19.5

M10

37.8 - 46.2

27.9 - 34.1

M12

63.0 - 77.0

46.5 - 56.8


The following information for electrical connection
applies to all terminal board connections with the
exception of terminal strips.

Tightening torques for

electrical connections

Thread

[Nm]

[ft lbs]

M4

0.8 - 1.2

0.59 - 0.89

M5

1.8 - 2.5

1.33 - 1.84


Especially for metal and plastic threaded cable
glands and pipe unions, the following values
apply:

Tightening torques for metal

threaded glands/unions

Thread

[Nm]

[ft lbs]

M12x1,5

4 - 6

2.95 - 4.43

M16x1,5

5 - 7.5

3.69 - 5.53

M25x1,5

6 - 9

4.43 - 6.64

M32x1,5

M40x1,5

8 - 12

5.9 - 8.85

Tightening torques for plastic

threaded glands/unions

Thread

[Nm]

[ft lbs]

M12x1,5

2 - 3.5

1.48 - 2.58

M16x1,5

3 - 4

2.21 - 2.95

M25x1,5

4 - 5

2.95 - 3.69

M32x1,5

M40x1,5

5 - 7

3.69 - 5.16





























Advertising