Installation

610.44434.40.000

14 / 32

© Gardner Denver Deutschland GmbH

Carry out the following work to install the pump-
motor unit:

 Installation and securing,
 Attachment of the included loose muffler if

necessary,

 Attachment of threaded flange or hose flange

(available as accessories)
for the connection of inlet or discharge pipe to
the muffler,

 Electrical

connection,

 Connection of inlet and discharge connection

to the system.



5.1 Installation

WARNING

For an installation that differs from the following
specifications, it is necessary to inquire with the
Service Department!


Ambient conditions:

The pump-motor unit is suitable for installation in
the following environments:
 In a dusty or damp environment,
 in

buildings,

 in the open.

When properly installed in the open, the
pump-motor unit must be protected from
exposure to intensive sunlight, e.g. by
attaching a protective roof. Otherwise, no
special protective devices against the effects
of weathering are required.


The drive motors of the pump-motor units have
the following design:
 with degree of protection IP55 (see rating

plate),

 with tropicalized insulation.

Installation conditions:

The pump-motor unit must be installed as
follows:

 on level surfaces,
 at a maximum height of 1000 m [3280 ft]

above sea level.
When installing at an altitude of more than
1,000 m [3,280 ft] above sea level, first inquire
with the Service Department.



Minimum distances:

To ensure sufficient cooling of the pump-motor
unit, it is absolutely necessary that the required
minimum distances to the fan guard and to the
face of the vacuum pump/compressor cover

be maintained. see Chapter 3.1, "Mechanical
data", Section "Minimum distances", Pg. 8.

The minimum distances to the face of the
vacuum pump/compressor cover are especially
important when installing on the vacuum
pump/compressor cover or near a wall.

CAUTION

To ensure sufficient cooling of the pump-motor
unit, also observe the following:
 Ventilation screens and openings must

remain clear.

 Discharge air of other units may not be

directly sucked in again!


Noise radiation:

To reduce the noise radiation, the following must
be observed:

 Do not mount pump-motor unit on noise-

conducting or noise-radiating parts (e.g. thin
walls or sheet-metal plates).

 Provide pump-motor unit with sound-

insulating intermediate layers (e.g. rubber
buffers under the base of the pump-motor
unit) if necessary.

 Install the pump-motor unit on a stable

foundation or on a rigid mounting surface.
This provides for smooth, low-vibration
running of the pump-motor unit.

Components for reducing noise on the pump-
motor unit:

Mufflers (included as standard equipment):

On delivery the pump-motor units are
equipped with attached mufflers as standard.
The noise radiation is considerably reduced
by the mufflers. See Fig. 2 to Fig. 9, Pg. 18 ff.

Additional silencer (available as an

accessory for the 2BH1):
The additional mufflers enable a further noise
reduction. They may only be used with free
entry and exit of gases, i.e. with direct intake
out of or direct feeding into the atmosphere
without piping

.