Commissioning

© Gardner Denver Deutschland GmbH

21 / 32

610.44434.40.000

6 Commissioning

WARNING

Improper use of the unit can result in serious or
even fatal injuries!
Have you read the safety precautions in Chapter 1,
"Safety", Pg. 3 f.? Otherwise you many not carry
out any work with or on the pump-motor unit!

WARNING

Danger from rotating parts (external fan, impeller,
shaft): Cutting/cutting off of extremities,
Grasping/winding up of hair and clothing!

Danger due to vacuum and gauge pressure:
sudden escape of fluids (skin and eye injuries),
sudden drawing in of hair and clothing!

Danger due to escaping fluid: Burns!
Start-up and operation only under the following conditions:
 The pump-motor unit must be completely

assembled. When doing so, pay particular
attention to the following components:

the vacuum pump/compressor cover,

the muffler on inlet and discharge
connections,

the fan guard.

 The pipes/hoses must be connected to inlet

and discharge connections.

 Inlet and discharge connections and the

connected pipes/hoses may not be closed,
clogged or soiled.

 Check the mounting elements, connections

of the pipe/hose connections, lines, fittings
and containers for strength, leaks and firm
seating at regular intervals.















6.1 Preparation

WARNING

Danger from closed connections!
With closed/soiled intake or discharge
connections vacuum or gauge pressure results
in the pump-motor unit.
This can overheat and damage the drive motor
winding.
Before start-up, make sure that the inlet and
discharge connections are not closed, clogged
or soiled!

CAUTION

Before starting up again after a longer standstill:
Measure the insulation resistance of the motor.
With values ≤ 1 kΩ per volt of nominal voltage,
the winding is too dry.


Measures before start-up:

 If a shut-off device is installed in the discharge

pipe:
Make sure that the unit is NOT operated with
the shut-off device closed.

 Before starting up the pump-motor unit,

observe the values specified on the rating
plate. Specifications on the drive-motor
nominal current apply at a gas entry and
ambient temperature of +40° C [104°F].

 Adjust the motor circuit breaker to the drive-

motor nominal current.


Check direction of rotation:

 The intended rotating direction of the shaft is

marked with arrows on the vacuum
pump/compressor housing (Fig. 1, Pg. 2,
Item. 7).

 The gas delivery direction is marked with

arrows on the inlet and discharge connections
(Fig. 1, Pg. 2, Item 6).

 Make sure the pipes/hoses on the inlet and

discharge connections are properly
connected.

 Switch the pump-motor unit on briefly and

then off again.

 Compare the actual rotating direction of the

external fan with the intended shaft rotating
direction indicated with the arrows shortly
before the pump-motor unit comes to a
standstill.

 If necessary, reverse the direction of rotation

of the motor.