Franklin Fueling Systems Colibri System Board Replacement User Manual

Colibri system board, Field replacement instructions

Advertising
background image

1 of 2

Colibri System Board

Field Replacement Instructions

Tools Needed

• ¼ Inch nut driver
• #2 Phillips screwdriver.

Backup Settings

If replacing a board that can still communicate, connect to

it and download setup, registration file and database.
To backup the data, use the TSA Upgrade tool. Refer

to INCON document 000-0075 for information about

downloading and using the upgrade tool. Individually

select the tabs Registration, Setup and Database and in

each case click Save.

Figure 1: Upgrade Tool Screen

Removing Existing System Board

1. Remove electrical power from unit at the breaker.
2. Remove the front cover from the unit.
3. Disconnect the plugs from the Power, Relay and

Probe receptacles and any communication cables

or USB sticks attached to communication ports.

4. Loosen the two screws on the left hand side of the

power brick (1 and 2 in Figure 2). Do not pull the

screws out.

5. Remove the two screws on the right hand side of

the board (4 and 5 in Figure 2) and set them aside

with the Intrinsically Safe shield and the display

ground strap.

6. Remove the standoffs from the top right and bottom

left corners of the board (3 and 4 in Figure 2).

7. Grasp the board and gently pull out from the top.

Once the top portion is an inch or so from the

enclosure gently lift the board up and out of the

enclosure.

Before placing the replacement board in the enclosure,

first remove the two lock nuts from the left hand side of the

power block/brick (1 and 2 in Figure 2) being careful that

the screws do not drop out. Use the two nuts to secure the

two screws on the unit that was removed. There will also

be a locknut under the standoff in location 4.
The replacement board that is being installed will be one of

two types:
• CL-MBXX Spare controller module, Fuel Management

System Application only, no software options

• CL-MBXX Replacement controller module, factory

programmed with the systems required options

If the system is having the board replaced with a spare

module, the board may need to be upgraded to regain

either SCALD or TRAC software options. This is only if the

original system had these software options included.
The TSA Upgrade tool can be used to upgrade the CL-

MBXX. For assistance with upgrades, contact the FFS

Technical Support Team.
If the CL-MBXX is ordered for the correct serial number

of the system, the board will have the necessary software

options installed. This will be a “plug and play” board

replacement.

Part #

Description

CL-MB

CL6 Replacement mainboard, no display

CL-MB/R

CL6 Replacement mainboard, no display

with required options

CL-MBWD

CL6 Replacement mainboard with display

CL-MBWD/R CL6 Replacement mainboard with display

and required options

Advertising