Installation, continued

1.4 Output Connector

The output connection is located on the front panel of the unit. Plug the 48VDC fiber node

into this connector.

1.5 Status Monitoring Connector

The Status Monitoring connector is located on the front panel of the unit. Associating with

this connector, an opto-coupler transistor array is connected between the output alarm pins

(Batt Low, Batt Miss, Repl Batt and AC Fail) and the ground pin (Tel Comm) as shown. In

the normal state, all the transistors are turned off and all the alarm pins are separated to

the ground. When an alarm is present, the micro controller will turn on the corresponding

transistor to short the alarm pin to the ground.