4 fuse replacement – Alpha Technologies AlphaGen DCX3000 - Operator's Manual User Manual

Page 21

Advertising
background image

041-028-B0-003, Rev. C

21

5.0

Engine Shut-Down and Cable Removal, continued

5.4 Fuse

Replacement

Tools and Materials Needed:

10mm and 8mm socket

• Ratchet

handle

• Torque

wrench

Replacement fuse: Alpha P/N 460-273-10, Hinode Electric Co. P/N 350GH-80

Procedure:

1. Set the ENGINE SW to OFF. Disconnect the extension

cable from the DC Out jack.

2. Remove the four 10mm nuts from the front plastic housing,

and remove the housing.

5. Remove the two 10mm nuts holding the fuse onto the fuse

holder. When reassembling, carefully tighten nuts to the
following torque specifi cations:
3.2 to 6.4 N m
2.4 to 4.7 ft-lbs.
28 to 56 in-lbs.

6. Replace fuse, and reassemble the generator in reverse

order.

3. Locate the fuse cover below the OUTPUT SW.

4. Remove the two 8mm bolts on the bottom of the fuse cover.

Remove the cover.

Advertising