0 specifi cations – Alpha Technologies AlphaGen DCX3000 - Operator's Manual User Manual

Page 9

Advertising
background image

041-028-B0-003, Rev. C

9

E

ngine

Honda GX 200 6.5 hp, air-cooled, OHV, single cylinder, manual recoil starting, manual choke

Fuel/Fuel Tank

Unleaded gasoline/3.5 gallon metal tank with level gauge

Rated Power

2800W continuous, 3000W maximum

Alternator

Permanent magnet, brushless, bearingless

Output Voltage
Dual range selector

36V: 39.5VDC, nominal at generator output connector
48V: 52.5VDC, nominal at generator output connector

Output Regulation

+/-1VDC

Control Features

Automatic Voltage Regulation

Electronic Governor

Overcurrent Protection

Analog voltmeter with back light

Cable Interface

Anderson type SBE-80 connector

Runtime

@25% load (48V): 15.4 hours
@25% load (36V): 17.5 hours
@100% rated load: 6.5 hours

Audible Noise

Approximately 65dBA @ 7 meters under full load

Frame

Fully enclosed

Dry Weight

117 lb

Dimensions

22" H X 17.6" W X 25.9" D (557mm x 447mm x 657mm)

Operating Temp

5°F to 104°F (-15°C to 40°C)

Required Accessories

Output Interface Cable: Available in 10', 30', or 50' lengths

Battery Interface Cable: Choose Ring Lug, Heavy-duty Alligator Clamp, or Y-adapter (Connects the

power supply’s battery input directly to the generator. See Section 3.0 for more
information)

Agency Compliance

CSA 22.2 No. 100-95
FCC part 15B Class A
CARB
UL 50, Section 30
NFPA 37, 70
EPA

Optional Accessories

Portable Generator Wheel Kit: P/N 745-793-20
Punch Tool Kit for Enclosures, 2.5" dia: P/N 745-131-20
Enclosure Upgrade Kit: P/N 745-131-21
Cable Bag and Cable Key Lanyard: P/N 745-764-21
Locking Handle: P/N 745-792-20

2.0 Specifi cations

Please refer to www.alpha.com for available options and data sheets.

NOTE:

Advertising