BTS Master™ MT8220T

Specifications

MT8220T TDS

PN: 11410-00698 Rev. B

3 of 28

Cable and Antenna Analyzer

(continued)

Distance-to-Fault

Vertical Range Return Loss

0 dB to 60 dB

Vertical Range VSWR

1 to 65

Fault Resolution (m)

(1.5

Ч

10

8

Ч

Vp) / ∆F (Vp = velocity propagation constant, ∆F is F2 - F1 in Hz)

Horizontal Range (m)

0 to (Data Points-1)

×

Fault Resolution, to a maximum of 1500 m (4921 ft)

Phase (1- and 2-Port)

Measurement Range

–180° to +180°

Resolution

0.01°

Smith Chart

Resolution

0.01

Measurement Accuracy

Corrected Directivity

> 42 dB

Measurement Uncertainty

Bias-Tee (Option 0010)

General

Setup

On/Off, Voltage, Current (Low/High)

Voltage Range

+12 V to +32 V

Current (Low/High)

250 mA/450 mA, 1 A surge for 100 ms

Resolution

0.1 V

PIM Analyzer

(Requires PIM Master™)

See MW8208A, MW8209A, MW8219A PIM Master Product Brochure 11410-00546

Reflection Magnitude Uncertainty

0.1

1

10

-40

-35

-30

-25

-20

-15

-10

-5

0

S

11

(dB)

Un

c

e

rt

a

in

ty

(

d

B

)

< 1 GHz

1-4 GHz

> 4-6 GHz

Transmission Magnitude Uncertainty

0.1

1

10

-80

-70

-60

-50

-40

-30

-20

-10

0

S

21

(dB)

Un

c

e

rt

a

in

ty

(

d

B

)

< 1 GHz

1-4 GHz

> 4-6 GHz