Model overview, Technical details – Atec EM-Test-Netwave-1-Phase Series User Manual

Page 2

Advertising
background image

DATA SHEET > NetWave Series 1-phase > 20130304

TECHNICAL DETAILS

MODEL OVERVIEW

1-PHASE NETWAVE-MODELS

NetWave 3

Multifunctional AC/DC source,
3,500VA AC / 4,500W DC

NetWave 7

Multifunctional AC/DC source,
7,500VA AC / 9,000W DC

NetWave 7.x

Multifunctional AC/DC source,
7,500VA AC / 9,000W DC,
with built-in isolation transformer
required to perform tests as per
aircraft (DO-160, Airbus and Boeing)
and military (MIL-STD-704)
standards

TECHNICAL DETAILS

NETWAVE 3

Output voltage

0V - 300V AC (RMS)
0V - +/-425V DC

Output current

12A (RMS) continuous
21A (RMS) short-term (max. 3s)
100A repetitive peak

NETWAVE 7

Output voltage

0V - 300V AC (RMS)
0V - +/-425V DC

Output current

26A (RMS) continuous
47A (RMS) short-term (max. 3s)
200A repetitive peak

NETWAVE 7.2 / NETWAVE 7.3*

Output voltage

0V - 360V AC (RMS)
0V - +/-500V DC

Output current
(@max. 300V AC)

26A (RMS) continuous
47A (RMS) short-term (max. 3s)
200A repetitive peak

* EXTENDED CAPABILITIES FOR NETWAVE 7.3

SourceAC mode

PLL synchronization with other
voltage sources

Trigger channel

Extended trigger functions

Segment "Step"

Ramping of voltage and/or frequency
in constant time windows

Extern mode

Control of the NetWave by an
external control signal

Simple Mode

Optimized control for integration of
the Netwave into existing
automation environments (for
example Matlab)

www.emtest.com