General specifications, General data – Atec EM-Test-Netwave-1-Phase Series User Manual

Page 3

Advertising
background image

DATA SHEET > NetWave Series 1-phase > 20130304

TECHNICAL DETAILS

GENERAL SPECIFICATIONS

SPECIFICATIONS

Output frequency

DC - 5,000Hz

Frequency
accuracy, stability

100ppm

DC offset with AC
signal

<20mV with linear load

Slew rate

8V/us

REGULATION

Voltage sense

Internal or external, 4 wires

Distortion (THD)

Less than 0.5%, @50/60Hz

Output voltage
stability

Better than 0.1%

Output voltage
accuracy

Better than 0.5%

Max. compensable
drop on wire

5% f.s.

Current limiter

2A to Imax for f < 75Hz (NetWave 3)
5A to Imax for f < 75Hz (NetWave 7.x)

Protection

Over current, over voltage,
over temperature, low voltage

OUTPUTS

DUT connection

4mm safety lab connectors
DUT adapter with connector
(depends on country of use)

DISPLAY AND CONTROLS

Display

2-Line LCD, 40 characters

LED indicators

Power On
Active output channel
Trigger
Functional status hard disk

Operation

6 function keys,
Test On key: ON/OFF key for the
power source

TRIGGER AND DUT MONITORING

Trigger

2 inputs, 2 outputs

DUT monitors

2 inputs, configurable

GENERAL SPECIFICATIONS

WAVEFORM GENERATOR

Segment types DC

DC, Ramp, Square, Triangle,
Sawtooth, Step, Sine, Sine sweep,
Sine ramp, Damped sinewave, Sine
ripple, Profile, Square sweep, Noise,
Sine Dwell, Sinc, Harmonic,
Exponent ...

Segment types AC

Sine, Modulation, Sine sweep,
Sweep on Sine, Sine up/down,
Overswing, Sine offset, Sine Dip,
Sine switching, Harmonic,
Interharmonic, Interharmonic step,
Harmonic distortion ...

Segment duration

Unlimited

GENERAL DATA

INTERFACES

GPIB, Ethernet
USB (for memory stick)
RS 232 (input from DPA analyser)
Frame bus (internal system bus)

AMBIENT CONDITIONS

Temperature

0°C - 40°C

Rel. humidity

10% - 90%, non condensing

MAINS

Supply voltage

3 x 400V (3P, N, PE);
3 x 208V (3P, N, PE) with option
MT-Netwave (NetWave 7) or
NetWave 7.x

Input current

32A (Phase 16A, Neutral 27A)

Line frequency

45Hz - 65Hz

Connector

CEE type 32A

DIMENSIONS

NetWave 3 /
NetWave 7

19", 9HU,
417mm x 449mm x 500mm,
45kg

NetWave 7.2/7.3

Minirack, 25HU,
600mm x 800mm x 1250mm,
120kg

www.emtest.com

© EM TEST > PAGE 3/5