13

Figure 4 - Remote Control Connector

(b) Solder 3 wires (22AWG) to pins 1, 2, and 3 of pin plug as shown in Figure 5.

Figure 5 - Pin Numbers

(c)

Make sure the load is disconnected and the power supply is OFF before
continuing to the next step. Otherwise, power supply may be damaged.

(d)

Plug the remote connector plug into the remote control terminal of the power
supply.

(e)

Secure the remote connector plug to the terminal socket by locking connector
ring (Figure 6).