B&K Precision 1693-1694 - Manual User Manual

Page 16

Advertising
background image

14

Figure 6 - Connector Ring

Then, you can choose either method A or B below to use the analog remote control

feature.


Method A: Using an External Variable DC Voltage Source

A variable external voltage source of 0 to 5 V is fed into the analog remote control
terminal to adjust the output voltage level of both Main and Auxiliary outputs.

WARNING: Do not input higher than 5 V, otherwise the overvoltage protection
(OVP) will be triggered.

1. Make sure the load is disconnected and the power supply is OFF.

2. Only use wires from pins 2 and 3. Connect pin 2 to positive polarity of the

external voltage source and pin 3 to negative polarity of the external voltage
source.

3. Turn the remote control ON/OFF switch to ON position.

4. Switch on the power supply.

5. Vary the external input voltage from 0 to 5 V to check and verify the full

output voltage range of the power supply.

6. Switch off the power supply.

Advertising