2 enable and disable the output, Enable and disable the output – B&K Precision 1693-1694 - Manual User Manual

Page 17

Advertising
background image

15

Method B: Using a 5 kΩ Variable Resistor

1. Make sure the load is disconnected and the power supply is OFF.

2. Prepare a 5 kΩ variable resistor and connect wires from pins 1, 2, and 3 as

shown in

Figure 7

.

Figure 7 - Variable Resistor Connection

3. Turn the remote control ON/OFF switch to ON position.

4. Switch on the power supply.

5. Adjust the 5 kΩ variable resistor from one end to the other to check and

verify the full output voltage range of the power supply.

6. Switch off the power supply.

5.4.2 Enable and Disable the Output


You can use pins 7 and 8 to remotely control the OUTPUT ON/OFF.

a) Open pins 7 and 8 if you want to ENABLE the output (by default).

b) Short pins 7 and 8 if you want to DISABLE the output.



Advertising