0x40 Set one of the step's current and time values

Byte

offset

Meaning

3 to 4

2 byte little-endian integer specifying which step number in the list

5 to 8

4 byte little-endian integer specifying the current in units of 0.1 mA

9 to 10

2 byte little-endian integer specifying the step timing in units of 0.1 ms

11-24

Reserved

0x41 Read one of the step's current and time values

Byte

offset

Meaning

3 to 4

2 byte little-endian integer specifying which step number in the list

5 to 8

4 byte little-endian integer specifying the current in units of 0.1 mA

9 to 10

2 byte little-endian integer specifying the step timing in units of 0.1 ms

11-24

Reserved

0x42 Set one of the step's voltage and time values

Byte

offset

Meaning

3 to 4

2 byte little-endian integer specifying which step number in the list

5 to 8

4 byte little-endian integer specifying the voltage in units of 1 mV

9 to 10

2 byte little-endian integer specifying the step timing in units of 0.1 ms

11-24

Reserved

0x43 Read one of the step's voltage and time values

Byte

offset

Meaning

3 to 4

2 byte little-endian integer specifying which step number in the list

5 to 8

4 byte little-endian integer specifying the voltage in units of 1 mV

9 to 10

2 byte little-endian integer specifying the step timing in units of 0.1 ms

11-24

Reserved

0x44 Set one of the step's power and time values

Byte

offset

Meaning

3 to 4

2 byte little-endian integer specifying which step number in the list

5 to 8

4 byte little-endian integer specifying the power in units of 1 mW

9 to 10

2 byte little-endian integer specifying the step timing in units of 0.1 ms

11-24

Reserved

8500 DC Load Series

Version: 030614

Page 63 of 77

Advertising