Dialight SL SERIES StreetSense LED Street Light User Manual

Street light “sl” series installation instructions

Advertising
background image

Document # 9100127149799 Rev.G

July 2012

Page 1 of 3

1501 Route 34 South, Farmingdale, NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 www.dialight.com

Dialig

ht de México S.R.L de C.V. Calle Lirios s/n Col. Carlos Pacheco, Ensenada Baja California, México C.P. 22830 +52 (646) 156-70-80

STREET LIGHT “SL” SERIES

INSTALLATION INSTRUCTIONS

100-277 VAC and 347-480 VAC

__________________________________________________________________________________________________________________________________________________________________________________________________

40/60/80 W Series

120/160 W Series

180/240 W Series

IMPORTANT

: Please read carefully before installation and retain for future reference

To prevent possible shock hazard, the fixture should be installed by a qualified licensed electrician.

All electrical connections must be in accordance with local codes, ordinances and National Electrical Code.

The use of safety protection such as safety eye glasses and protective gloves are recommended

Proper grounding of the fixture is essential for protection from shock, correct operation and the elimination of electrical
interference.

DANGER: RISK OF ELECTRICAL SHOCK. TURN OFF MAIN POWER SOURCE BEFORE SERVICE

INSTALLATION STEPS:
1- Open access cover 1 by unsnapping the latch 2 and allow access cover 1 to dangle *

ATTENTION: Do not remove the access cover 1 once mounted on arm it may be difficult to replace

2- Slip the fixture onto arm

ATTENTION: Loosening of the [4] bolts on the arm bracket 3 may be required
• Using the different arm rest levels on the base 4 rest the arm on the proper rib to level the fixture.

Ribs allow fixture to be adjusted in 2-1/2° increments +5° +2 1/2° 0° -2 1/2° -5°

3- Level fixture and tighten the [4] bolts on the bracket 3 in a ‘star’ pattern until fixture is secured on arm [

15 ft/lb [20.3 Nm] suggested

]

4- Connect source wires to terminal block 5 as shown in wiring schematic

• Wiring instructions are also available on a label on the surface of the access cover 1 .
• CONNECT THE SOURCE GROUND WIRE TO TERMINAL
• CONNECT THE SOURCE NEUTRAL/LIVE2 WIRE TO TERMINAL - "N" or “L2”
• CONNECT THE SOURCE LIVE/LIVE1 WIRE TO TERMINAL - "L" or “L1”

ENSURE ALL WIRE TERMINAL SCREWS ARE TIGHTENED

WARNING: 480 VAC FIXTURES CAN NOT BE CONNECTED TO SINGLE PHASE

5- Once source wires are connected, restore power and check for illumination

CAUTION

: Do not look directly into fixture once powered and lit. Use protective shaded eye wear when viewing

6- Close the access cover 1 re-engage and snap the latch 2 closed. *

* in some designs the removal and re-attachment of security screw is required