Dialight 860-xxxx Vigilant L-810 Red LED Obstruction Lights User Manual

Obstruction / visual signal light

Advertising
background image

Document No: 9100-127-1112-99 REV B

Issued: April 03, 2009

Sheet 1 of 2

OBSTRUCTION / VISUAL SIGNAL LIGHT

SINGLE and DUAL FIXTURES

INSTALLATION INSTRUCTIONS and PARTS LIST

1501 Route 34 South, Farmingdale, NJ 07727 USA Tel: [+1] 732-919-3119 Fax: [+1] 732-751-5778 www.dialight.com

PART No:
860-1x01-00x

120 VAC, Single or Dual

860-1x02-00x

240 VAC, Single or Dual

860-1x03-00x

12 VDC, Single or Dual

860-1x04-00x

48 VDC, Single or Dual

860-1x02-00x EU

230 VAC, Single or Dual, Europe

860-1x05-00x

24 VDC, Single or Dual

860-1x06-00x

10-27 VDC, Single or Dual

860-1R01-001-FAA

120 VAC, Single

860-3x03-00x

12 VDC, Single or Dual, Low Watt

860-4x02-00x

240 VAC, Single or Dual, 50 cd

860-4x02-00x EU

230 VAC, Single or Dual, Europe

860-5x02-00x

240 VDC, Single or Dual, 10 cd

860-6x01-001

120 VAC, Single or Dual, Canada

860-7X02-002

240 VDC, Dual, Australia

860-8x04-001

48 VDC, Single, Sweden

[last 3 digits ... 001 = Single 002 = Dual]

WARNING:
DE-ENERGIZE CIRCUIT BEFORE INSTALLING OR WORKING ON FIXTURE

CAUTION
To retain seal integrity (and preserve warranty) do not loosen or remove the clamp holding the light assembly together

REMOVAL OR LOOSENING OF THE CLAMP WILL VOID ALL WARRANTIES

The light assembly fixture can be mounted in any position. When mounted 'upright' [as illustrated] the fixture will meet the designed
optical specifications for Aircraft Obstruction Warnings. When mounted in any other position, the fixture will not meet the designed
optical specifications mentioned and will be considered as a visual signal fixture.

SINGLE FIXTURE INSTALLATION STEPS:

The single housing 2A has a 1” NPT [3/4" bushing] end to be assembled to conduit … right angle or vertical

o

Use a 1-1/2” wrench to attach and tighten the single housing 2A to the conduit

o

Use the 1” NPT plug 4 to close threaded opening not being used

o

Remove reducing bushing 5 if threading into 1” NPT conduit

Feed the supply wires through the conduit and single housing 2A leaving approx 6” of wire for termination inside the single
housing 2A .

Electrically connect the supply wires to the light assembly 1 wires

o

Connect the light assembly wire (with voltage label) to the Hot AC or Positive [+] line

o

Connect the light assembly wire [without label] to the Neutral AC or Negative [-] line

o

Connect the grounding wire [from green screw] to the Ground line

Tuck the connected wires inside the single housing. 2A .

Position light assembly 1 on the wire single housing 2A and use the holding
screws 3 to secure the light assembly in place

Restore power and verify operation























Advertising